en:netzer:s88 [2012/02/06 23:43]
svesch
en:netzer:s88 [2012/02/17 16:32]
svesch GPIO settings added.
Line 44: Line 44:
 Netzer with installed IO firmware (at least Release *1.5pro*) must be configured via the webinterface:​ Netzer with installed IO firmware (at least Release *1.5pro*) must be configured via the webinterface:​
   - SPI-Master-Mode on the common page (restarting Netzer afterwards is needed)   - SPI-Master-Mode on the common page (restarting Netzer afterwards is needed)
-  - SPI-Master-settings: Frequency on 5 kHz (for long lines also 1.3 kHz may be tried), SPI mode 2 (Idle state of the clock signal is 1, data is stored on falling edge), sampling of the data in the middle of clock cycle (see picture) ​ +  - SPI-Master settings: Frequency on 5 kHz (for long lines also 1.3 kHz may be tried), SPI mode 2 (Idle state of the clock signal is 1, data is stored on falling edge), sampling of the data in the middle of clock cycle (see picture) ​\\ {{s88_spisettings.gif?​nolink&​|SPI Einstellungen}} \\ \\  
- +  - GPIO settings: In this example SPI_INT and SPI_CS are use as digital outputs. Configure them via the GPIO settings dialog! {{s88_gpio.gif?​nolink&​|GPIO settings}}
-{{s88_spisettings.gif?​nolink&​|SPI Einstellungen}}+
  
  