Table of Contents

Reset to factory settings

The factory settings

The factory settings are:

Further settings depend on the project. Read more about them at the appropriate project pages.

Reset to factory settings at Netzer

Usually the Netzer can be reset to factory settings via the start page of the webinterface. If the administrator password is lost or the IP settings are wrong, Networker can no longer be configured or updated. In that case the Netzer configuration can be reset to factory settings directly at the Netzer hardware.

Releases older than 1.5

The PGD pad should be pulled down with a resistor (1K) to ground during a Netzer restart.

As soon as Netzer “hangs” (meaning does nothing) the installed resistor must be removed. If Networker starts flashing the network jack LEDs the reset was successful. Afterwards a restart is performed.

Release 1.5

Reset to factory settings with resistor is no longer supported.

For resetting to factory settings the erase_eeprom project is uploaded via TFTP, like described here.