Netzer is able to generate and capture signals at IO3 and SPI_INT. | Netzer is able to generate and capture signals at IO3 and SPI_INT. | ||
- | {{ : | + | {{ : |
The image shows the structure of the impulse generator/ | The image shows the structure of the impulse generator/ | ||
- | The impulse module is divided into two fundamental | + | The impulse module is divided into two modes, the unsynchronized mode and the IO0 synchronized mode. |
- | Both, IO3 and SPI_INT, can either work in unsynchronized or in IO0 sync mode. | + | Both, IO3 and SPI_INT, can either work in unsynchronized or in IO0 synchronized |
- | Furthermore | + | Furthermore a mode M can be configured: |
* Continuous mode | * Continuous mode | ||
- | * Single | + | * Single |
- | * IO0 triggered mode | + | * Triggered by IO0 |
- | And last but not least channels | + | Resolution N can be either 100ns, 200ns, 400ns or 800ns. |
+ | All raw values associated with Capture/ | ||
+ | Last but not least channels can be configured for capturing (measuring impulses) or generating impulses. | ||
- | ===== Unsynchronized mode ===== | + | |
+ | ===== Examples | ||
+ | |||
+ | Some of the examples below show both signals IO3 and SPI_INT. | ||
+ | Of course impulse module can be configured to use only one of them. | ||
+ | |||
+ | The examples below only show positive logic. | ||
+ | Simply invert the signals to get negative logic examples. | ||
+ | |||
+ | In the IO0 examples the IO0 trigger is configured for rising edge. | ||
+ | Simply invert the IO0 signal to get falling edge examples. | ||
+ | |||
+ | |||
+ | ==== Generating impulses in continuous mode (Unsynchronized) | ||
The impulse timer is free running in this mode. | The impulse timer is free running in this mode. | ||
- | IO0 interrupts | + | Changes on IO0 will not reset the impulse timer. |
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Generating impulses in single mode (Unsynchronized) ==== | ||
+ | |||
+ | The impulse timer is free running in this mode. | ||
+ | Changes on IO0 will not reset the impulse timer. | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Generating impulses in " | ||
+ | |||
+ | This mode shall not be used. | ||
+ | |||
+ | ==== Generating impulses in continuous mode (IO0 synchronized) ==== | ||
+ | |||
+ | This mode shall not be used. | ||
+ | |||
+ | |||
+ | ==== Generating impulses in single mode (IO0 synchronized) ==== | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Generating impulses in " | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Measuring impulses in continuous mode (Unsynchronized) ==== | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Measuring impulses in single mode (Unsynchronized) ==== | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ==== Measuring impulses in " | ||
+ | |||
+ | This mode shall not be used. | ||
+ | |||
+ | |||
+ | ==== Measuring impulses in continuous mode (IO0 synchronized) ==== | ||
+ | |||
+ | This mode shall not be used. | ||
+ | |||
+ | |||
+ | ==== Measuring impulses in single mode (IO0 synchronized) ==== | ||
+ | {{ : | ||
- | ==== Generating impulses in continuous mode ==== | ||
+ | The second example shows the special case of an ultrasonic sensor like HC-SR04. | ||
+ | This sensor needs a 10 µs impulse at the TRIG input which shall be connected to IO3. | ||
+ | The pulse length of sensor singnal ECHO decodes the distance to the detected object. | ||
+ | The signal must be connected to IO0 and SPI_INT. | ||
+ | IO0 must be configured for rising trigger edge, SPI_INT for falling capture edge. | ||
+ | {{ : | ||
+ | ==== Measuring impulses in „Triggered by IO0“ mode (IO0 synchronized) ==== | ||
+ | In this mode the periode of periodic signals or pulse length can be measured. | ||
+ | Connect the signal to measure to IO0 and IO3 or SPI_INT or both. | ||
+ | For period length the IO0 trigger edge and the capture edge must be equal (like IO3 in image below). | ||
+ | For positive pulses the IO0 trigger edge must be rising, the capture edge falling edge (like SPI_INT in image below). | ||
+ | For negative pulses the IO0 trigger edge must be falling, the capture edge rising edge. | ||
+ | {{ : | ||