Buy NetzerContact Netzer

Users

Index

  1. Authorization
  2. Reset to factory settings
  3. Firmware updates
  4. Networker IO
  5. Manuals
  6. Networker Website

Authorization

Since Version 1.3 a Networker web access must be authorized with username and password. Three different user accounts are differentiated:

Do not forget to alter usernames and passwords in the user administration dialog!

Reset to factory settings

The factory settings are:

Reset to factory settings at Networker Usually the Networker can be reset to factory settings via the start page of the webinterface. If the administrator password is lost or the IP settings are wrong, Networker is not configurable nor updateable anymore. In that case the Networker configuration can be reset to factory settings directly at the Networker hardware. The PGD pad should be pulled down with a resistor (1K) to ground during a Networker restart. As soon as Networker "hangs" (means does nothing) the installed resistor should be removed. If Networker starts flashing the network jack LEDs the reset was successful. Afterwards a restart is performed.

Go to top

Firmwareupdates

The firmware is constantly under development. New features arrive and bugs will be fixed. The releases are published here as intel hex files:

The Networker web interface is available in English, too.

Updates in operation mode

The update is done with a PC via the network. The hex file should be stored to hard disk before. The file is transfered to the Networker via tftp. For the update therefore a tftp client is needed. At the most operating systems such a client is included.

Since Version 1.3 the Firmware update has to be explicitly activated via the Networker web interface (logged in as administrator). This eliminates a potential security risk of Networker. In the common settings a radio group can be found:

Webinterface screenshot

The file is transfered to Networker with the TFTP PUT command. Networker is accessed via the current IP address or the network name. Example for a tftp command in a shell box under Windows:

tftp ne7C4000.local put "Netzer.hex"

Networker goes into the update mode automatically and the file is transfered. A running transfer is indicated through the network activity LED, which is emitting for about 20 seconds. After the transfer has finished successfully the tftp client prints out that message:

Successfully transfered: 335139 bytes in 16 seconds, 20946 bytes/s

Updates in bootloader mode

The bootloader mode is active for aprox. 2 seconds after power on. After this time Networker enters the operation mode. The active mode is indicated due the fast blinking network LED. In bootloader mode Networker has the fixed IP address 192.168.97.60 and MAC address 00-04-A3-00-00-00. Updating only works if this IP address is not already occupied. The updating process works analog to the update in operation mode.

Important: Only one Networker is allowed to be in Bootloader mode when starting the update.

Go to top

Networker IO

Here is a short overview over the 13 available pins of Networker.

Networker NamePIC PinMaximum output currentMaximum input voltageDescription
SPI_INTRC225 mA5.5 VInterrupt pin of the SPI module (only used in SPI slave mode) - PWM output
SPI_CLKRC325 mA5.5 VClock line of the SPI module
SPI_MIRC425 mA5.5 VData input of the SPI module
SPI_MORC525 mA5.5 VData output of the SPI module
SPI_CSRF72 mA5.5 VSelect line of the SPI module (only used in SPI slave mode)
RXRC725 mA5.5 VUART Receive line
TXRC625 mA5.5 VUART Transmit line
IO0RB025 mA5.5 VInterrupt input
IO1RB125 mA5.5 VInterrupt input
IO2RB225 mA5.5 VInterrupt input
IO3RD18 mA5.5 VPWM output
IO4RA22 mA3.3 VADC input
IO5RA32 mA3.3 VADC input

Go to top

Manuals

A detailed manual is printed in the Elektor journal of December. Elektor has uploaded a project website, there the articel also can be bought online: Link

Go to top

Networker Website

On the Networker websites common settings can be done and informations can be requested. For a first try this websites were mirrored to this project pages (from the latest release, logged in as administrator). Here is the link to the website: Link

Go to top